Ferrule - FWP 22 x 58mm 690V/700V (IEC/UL): 20-100A, Striker Optional
New - gR operating class with and without striker
Eaton's Bussmann series FWP 14x51mm class gR fuses provide full range overload and short-circuit protection and are used to protect AC/DC drives and semi conductors.
They are available with an optional striker to provide local indication of fuse status or work in CH22 modular fuse holder to provide remote fuse indication capabililty.
aR operating class with and without striker
Eaton's Bussmann series FWP 22x58mm class aR fuses provide short-circuit protection and are used to protect AC/DC drives and semi conductors.
They are available with an optional striker to provide local indication of fuse status or work in the CH22 modular fuse holder to provide remote fuse indication capabililty.
Description:Ferrule style high speed fuses. with and without indicating striker.
Ratings:
Volts: 690Vac (IEC); 700Vac (UL)
Amps: 20-100A
IR: 200kA RMS Sym. 50kA @ 500Vdc
Agency Information: CE, UL Recognition
Features and Benefits
• Excellent cycling capability and dc performance
• Low arc voltage and low energy let-through (I2t)
• Low watts loss in a compact size
• Used with finger-safe holders/blocks
Typical Applications
• DC common bus
• DC drives
• Power converters/rectifiers
• Reduced voltage starters
Catalog Numbers
Fuse type |
Fuse symbol |
Rated voltage |
Rated current (amps) |
12t (A2s) |
Watts loss (w) * |
Catalog no |
|
Pre-arcing |
Clearing at 600 Vac |
||||||
without striker |
22 * 58mm (7/8*2-9/32) |
700 Vac/dc (UL) |
20 |
23 |
390 |
5 |
FWP-20A22F |
25 |
37 |
630 |
6 |
FWP-25A22F |
|||
32 |
55 |
780 |
8 |
FWP-32A22F |
|||
40 |
88 |
960 |
12 |
FWP-40A22F |
|||
50 |
155 |
2200 |
12.5 |
FWP-50A22F |
|||
63 |
280 |
4000 |
15 |
FWP-63A22F |
|||
80 |
550 |
7800 |
15 |
FWP-80A22F |
|||
100 |
1100 |
15600 |
16.5 |
FWP-100A22F |
|||
with striker |
22 * 58mm (7/8*2-9/32) |
700 Vac/dc (UL) |
20 |
19 |
260 |
6 |
FWP-20A22FI |
25 |
34 |
410 |
6 |
FWP-25A22FI |
|||
32 |
53.5 |
605 |
8 |
FWP-32A22FI |
|||
40 |
68 |
760 |
9 |
FWP-40A22FI |
|||
50 |
135 |
1600 |
9.5 |
FWP-50A22FI |
|||
63 |
280 |
3080 |
11 |
FWP-63A22FI |
|||
80 |
600 |
6600 |
13.5 |
FWP-80A22FI |
|||
100 |
1100 |
12500 |
16 |
FWP-100A22FI |
Without StrikerCatalog Numbers (Amps)
Catalog Numbers |
Catalog Numbers |
Catalog Numbers |
Catalog Numbers |
FWP-20A22F |
FWP-32A22F |
FWP-50A22F |
FWP-80A22F |
FWP-25A22F |
FWP-40A22F |
FWP-63A22F |
FWP-100A22F |
With StrikerCatalog Numbers (Amps)
Catalog Numbers |
Catalog Numbers |
Catalog Numbers |
Catalog Numbers |
FWP-20A22FI |
FWP-32A22FI |
FWP-50A22FI |
FWP-80A22FI |
FWP-25A22FI |
FWP-40A22FI |
FWP-63A22FI |
FWP-100A22FI |
Electrical Characteristics
Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).
Arc Voltage
This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%.
Power Losses
Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.
Carton Quantity
Amp Rating |
Carton Qty |
20-100 |
10 |
*IEC/UL Voltage rating 690/700
Series: FWP series, cylindrical fast fuse 22 x 58mm
Current: 20-100A
Voltage: 690Vac (IEC), 700Vac (UL)
Size: 22 x 58mm
Breaking capacity: 200kA RMS Sym., 50kA @ 500Vdc
Certification: CE, UL