Einfacher Kauf

Bonjour Invité! Sign up to our mailing list.

086 159 6228 5577

Emergency 24/7 Fuse Service
At Einfacher Kauf, our in-stock fuses are guaranteed to ship same-day – so you get the fuses you need, exactly when you need them.

Technical Disclaimer:
The catalog number(s) suggested in the Bussmann series Fuse Selector represents the closest Bussmann series fuse(s) based upon the entered selected search attributes. It is the responsibility of the user to review the product specifications to determine suitability for the intended application.

Eaton's Bussmann

Ferrule - FWC 600V: 6-32A style high speed fuses

 

Specifications Description: Ferrule style high speed fuses.

Dimensions: See dimensions illustration.

Ratings:

• Volts 600Vac/dc

• Amps: 6-32A

• IR:

• 200kA RMS Sym.

• 50kA @ 700Vdc (6-25A)

Agency Information: CE, UL Recognition: 6-32A. UL Recognition: 6-25A

Fuse symbol

Rated voltage

Rated current (amps)

12t (A2s)

Watts loss (w) *

Catalog no

Pre-arcing

Clearing at 600 Vac

10 * 38mm (13/32x1-1/2)

700 Vac/dc (UL)

1

0.2

1.2

0.5

FWC-1A10F

2

0.5

3

1.2

FWC-2A10F

3

1.6

11

1.5

FWC-3A10F

4

5.2

32

1.5

FWC-4A10F

600Vac/700Vdc (UL)

6

4

30

1.5

FWC-6A10F

8

6

50

2

FWC-8A10F

10

9

70

2.5

FWC-10A10F

12

15

120

3

FWC-12A10F

16

25

150

3.5

FWC-16A10F

20

34

260

4.8

FWC-20A10F

25

60

390

6

FWC-25A10F

600Vac (UL)

32

95

600

7.5

FWC-32A10F

Electrical Characteristics

Total Clearing I2t The total clearing I2t at rated voltage and at power factor of 15% are given in the electrical characteristics. For other voltages, the clearing I2t is found by multiplying by correction factor, K, given as a function of applied working voltage, Eg, (rms).

Arc Voltage

This curve gives the peak arc voltage, UL, which may appear across the fuse during its operation as a function of the applied working voltage, Eg, (rms) at a power factor of 15%.

Power Losses

Watts loss at rated current is given in the electrical characteristics. The curve allows the calculation of the power losses at load currents lower than the rated current. The correction factor, Kp, is given as a function of the RMS load current, Ib, in % of the rated current.

Catalog Numbers (Amps)

Catalog Numbers

Catalog Numbers

Catalog Numbers

FWC-6A10F

FWC-12A10F

FWC-25A10F

FWC-8A10F

FWC-16A10F

FWC-30A10F

FWC-10A10F

FWC-20A10F

FWC-32A10F

Carton Quantity

Amp Rating

Carton Qty.

6-32

10

Features and Benefits

• Excellent cycling capability and DC performance

• Low arc voltage and low energy let-through (I2t)

• Low watts loss in a compact size

• Used with finger-safe holders/blocks

Typical Applications

• DC common bus

• DC drives

• Power converters/rectifiers

• Reduced voltage starters

 

PRE - ORDER NOW
Manufacturer Part No: FWC-* A10F
Series: FWC series, cylindrical quick fuse 10 x 38mm
Current: 6-32A
Voltage: 600Vac/dc
Size: 10 x 38mm
Breaking capacity: 200kA RMS Sym., 50kA @ 700Vdc (6-25A)
Certification: CE, UL Recognition: 6-32A. UL Recognition: 6-25A

Request For Quote

*Please reply us if you are interested so we can send you our complete quotation which includes prices, moq, packaging, delivery time, payment terms etc.
*Please fill in your detailed information in all required fields.we will contact you via email within 2 hours.
*If you have any questions, please leave a message or send an email service@cooper-bussman.com.cn

 

Code

FWC Series Cylindrical Quick Fuse 10 x 38mm